Fourplex code: the draft for the Dec. 3 hearing adds the building board's smoke alarm and outlet rules, and lists a bigger size cap
The Building and Fire Code Board of Appeals backed the three- and four-unit code change 6-1 with two safety additions. Both appear in the draft ordinance, which also sets an 8,000-square-foot limit where the staff summary says 6,000. A vote comes later.
The City Council holds a public hearing Dec. 3 on letting small three- and four-unit buildings be permitted under the residential building code, the code for houses and duplexes, instead of the commercial code used for apartment complexes. It is Item 63 on the Dec. 3 draft agenda, and the backup posted Friday shows the proposal has changed since we first described it.
The building board's vote
On Nov. 19 the Building and Fire Code Board of Appeals recommended adopting staff's draft "with additional provisions for enhanced life safety." The vote was 6-1, with board member Alan Schumann voting no and Chair Oren Mitzner abstaining. The board asked for two things:
- Interconnected smoke alarms in every unit, "regardless of configuration or if common egress space is included in the design," so all occupants get warning of a fire in any unit.
- No electrical outlets in shared stairs and halls. The board said this would make it less likely that "devices such as lithium-ion batteries" are left plugged in there unattended. The council's July resolution had suggested the same thing.
What the draft ordinance now says
The draft ordinance in the Dec. 3 backup contains both:
- Section BP303.3: "Electrical receptacles are prohibited in a common egress space."
- Section BP310: "Each dwelling unit and common egress space shall contain a notification appliance that is connected to smoke alarms located in other dwelling units."
The staff presentation from a Nov. 12 public session, also in the backup, had required interconnected alarms only "when units are stacked or when there is a Common Egress Space."
Advertisement
Two numbers that don't match
The draft defines a qualifying building as one that "does not exceed 8,000 square feet in gross floor area." The recommendation for action and the November presentation both say 6,000 square feet. The backup does not explain the difference. The council could settle it when it votes on the ordinance.
The draft also says the ordinance would take effect March 1, 2027.
What stayed the same
The core of the proposal, as listed in the staff summary and the draft:
- Sprinklers under the NFPA 13D residential standard, with added coverage for attached garages, shared stairs and halls, and covered wood balconies and decks.
- Fire-rated walls and floors between units, with no reduction for having sprinklers.
- Shared stairs and halls that lead directly outside, enclosed in one-hour construction, with 45-minute, self-closing, gasketed doors.
- No more than two units stacked, no habitable attics above the third story and no shared rooftop decks.
- Access agreements so a contractor or code official can inspect fire systems in units owned or occupied by others.
How the vote works
State law requires three separate council meetings, the recommendation says. The council set the hearing on Nov. 19 by an 11-0 vote. Dec. 3 is the hearing only. Adoption "may" come "at a future meeting," with no date given.
Advertisement
The council started this with Council Member Krista Laine's resolution on July 23, which passed 9-1, with Council Member Marc Duchen voting no and Council Member Vanessa Fuentes absent. At that meeting the city's chief building official said "zoning is what restricts fourplexes at this point." The code change does not change how many homes zoning allows on a lot.
How to weigh in
Development Services is taking comments through its online feedback page, listed in the presentation, and speakers can sign up for Item 63 on Dec. 3. The staff contacts are Deputy Building Official Steve Leitch and program manager Raistlin Chiovaro.